COEN Fire Detection Renovation Case
Background of the project
◆ Boiler information: 2X330 MW W flame boiler
◆ Manufacturer: FOSTER WHEELER, USA
◆ Number of coal burners: 24
◆ Number of oil burners: 24
There is a problem
◆ The detection signal of the original equipment is weak, the signal is unstable, the anti-interference ability is poor, and the failure rate is high;
◆ The original equipment cannot detect the flame when the load is low, and the product has poor adjustability and adaptability, and cannot adapt to complex combustion conditions;
◆ Spare parts Expensive and long delivery time;
Solution
◆ Replace the original COEN's iScan fire detector with Safe-Fire's W-FLAME series fire detector, which has stable performance and strong anti-interference ability;
◆ W-FLAME fire detector can adjust the bandwidth, frequency, gain and other parameters in real time. Accurately detect the burning condition of the target flame;
◆ Safe-Fire's W-FLAME series fire inspection has a short delivery cycle and high cost performance.
On-site installation photos
Transformation of the former
After transformation
Specifications
product name |
iScan |
W-FLAME |
brand name |
COEN |
SAFE-FIRE |
Spectral response range |
400-3300nm |
900-1700nm |
signal processing technology |
microprocessor |
DSP high speed microprocessor |
Operating environment temperature |
-20℃-+70℃ |
-40℃-+85℃ |
Protection level |
IP66 |
IP66 |
Debugging mode |
Use potentiometer for parameter setting |
Panel debugging, network debugging |
Detection performance |
Detect AC (flicker amplitude) and frequency signals, no bandwidth settings, frequent debugging is required after coal quality changes |
AC (flicker amplitude) and frequency signals, with bandwidth settings to prevent mixed detection of kerosene, prevent low-load peeking, strong adaptability |
output signal |
"Fire" switch value, fault alarm, flame intensity: 4-20mA |
"Fire" switch value, fault alarm, flame intensity: 4-20mA |
Result
◆ The fire detection signal detection is stable, which improves the safety of the fire detection system;
◆ The fire detection protection is put into normal operation, improving the safety of the boiler;
◆ The fire detection probe does not need to be debugged, reducing the maintenance workload and improving the user experience.